ROOTCASTLE / ENGINEERING LAB

Signal systems

Sampling, windowing and frequency analysis.

SIMULATED · NOT LIVE TELEMETRY

Vibration / FFT

Model and assumptions

512 samples; deterministic sinusoids and seeded noise. FFT is one-sided peak amplitude, not RMS. Δf = fs/N. Hann coherent gain is corrected; spectral leakage can remain. The 4.7× component is not a physical bearing-fault model.

Educational model. Results are not sufficient to diagnose a machine or establish safe operating limits.

Method reference: NI — Understanding FFTs and Windowing ↗

← Rootcastle LAB